| pH Range | -2.000 to 20.000 pH |
|---|
| pH Resolution | 0.1, 0.01, 0.001pH |
|---|
| pH Accuracy | ±0.002 pH |
|---|
| pH Calibration | Up to 6 Points |
|---|
| pH Standard Customization | Included |
|---|
| pH Calibration Reminder | Included |
|---|
| pH Slope Limit | Included |
|---|
| pH Standard Recognition | NIST, GB, DIN, USA, JIS Buffers |
|---|
| mV / ORP Range | -2000.00 to 2000.00 mV |
|---|
| mV / ORP Resolution | 0.1, 0.01 mV |
|---|
| mV / ORP Accuracy | ±0.1 mV or ±0.03 % |
|---|
| EH ORP Mode | Included |
|---|
| ORP Calibration Points | 1 custom point (relative mV) |
|---|
| pX Range | -2.000 to 20.000 pX |
|---|
| pX Resolution | 0.1, 0.01, 0.001 pX |
|---|
| pX Accuracy | ±0.002 pX |
|---|
| pX Calibration | Up to 6-Point Calibration |
|---|
| ISE Range | 1.000E-9 to 9.999E9 |
|---|
| ISE Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb |
|---|
| ISE Resolution | Up to 4 significant digits |
|---|
| ISE Accuracy | ±0.3 % |
|---|
| ISE Calibration | Up to 6-Point Calibration |
|---|
| Conductivity Range | 0.000 μS/cm to 2000 mS/cm |
|---|
| Conductivity Resolution | 0.001 μS/cm minimum, changed with range |
|---|
| Conductivity Accuracy | ±0.5% of full scale |
|---|
| Conductivity Calibration Point | Up to 5-Point Calibration |
|---|
| Conductivity Standard Recognition | 146.5 μS/cm, 1408 μS/cm, 12.85 mS/cm, 12.85 mS/cm; 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm |
|---|
| Conductivity Reference Temperature | 5, 10, 15, 18, 20, 25 ºC |
|---|
| Resistivity Range | 5.00Ω·cm ~ 100.0MΩ·cm |
|---|
| Resistivity Resolution | 0.01Ω·cm minimum |
|---|
| Resistivity Accuracy | ±0.5% of full scale |
|---|
| TDS Range | 0.000 ppm ~ 1000 ppt |
|---|
| TDS Resolution | 0.1ppt |
|---|
| TDS Accuracy | ±0.5% of full scale |
|---|
| Salinity Type | NaCl |
|---|
| Salinity Range | 0.00 to 80.0 ppt (NaCl equivalent) |
|---|
| Salinity Resolution | 0.1ppt |
|---|
| Salinity Accuracy | ±1ppt |
|---|
| Temperature Range | -10 to 135 ºC, 14 to 275 ºF |
|---|
| Temperature Unit | °C / °F |
|---|
| Temperature Resolution | 0.1 °C |
|---|
| Temperature Accuracy | ±0.1 °C |
|---|
| Reading Mode | AutoRead (Fast/Medium/Slow), Timed, Continuous measurement supported |
|---|
| Reading Prompts | Displays "Reading," "Stable," and "Locked" indicators |
|---|
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
|---|
| GLP Features | Calibration Log, Timestamping |
|---|
| Data Storage | 1000 Groups |
|---|
| pH Electrode Inputs | BNC (Q9) |
|---|
| Temp./DO Probe Inputs | 4-pin Aviation Connector |
|---|
| Temp./EC Probe Inputs | 5-pin Aviation Connector |
|---|
| Reference Electrode | Banana |
|---|
| Outputs | USB 2.0 (Flash memory device, PC, Scanner) & RS 232 (Printer, Autosampler) |
|---|
| Display Backlight | Included |
|---|
| Auto Power Off | 1~60 min, off |
|---|
| IP Rating | IP54 Water Resistant |
|---|
| Date and Time | Included |
|---|